Linux - hpacucli
This document is a quick cheat sheet on how to use the hpacucli
utility to add, delete, identify and repair logical and physical disks
on the Smart array 5i plus controller, the server that these commands
were tested on was a HP DL380 G3 server with a Smart Array 5i plus
controller with 6 x 72GB hot swappable disks, the server had Oracle
Enterprise Linux (OEL) installed.After a fresh install of Linux I downloaded the file hpacucli-8.50-6.0.noarch.rpm (5MB), you may want to download the latest version from HP. Then install using the standard rpm command.
I am not going to list all the commands but here are the most common ones I have used thus far, this document may be updated as I use the utility more.
Utility Keyword abbreviations
|
|
Abbreviations | chassisname = ch controller = ctrl logicaldrive = ld physicaldrive = pd drivewritecache = dwc |
hpacucli utility
|
|
hpacucli | # hpacucli # hpacucli help Note: you can use the hpacucli command in a script |
Controller Commands
|
|
Display (detailed) | hpacucli> ctrl all show config hpacucli> ctrl all show config detail |
Status | hpacucli> ctrl all show status |
Cache | hpacucli> ctrl slot=0 modify dwc=disable hpacucli> ctrl slot=0 modify dwc=enable |
Rescan | hpacucli> rescan Note: detects newly added devices since the last rescan |
Physical Drive Commands
|
|
Display (detailed) | hpacucli> ctrl slot=0 pd all show hpacucli> ctrl slot=0 pd 2:3 show detail Note: you can obtain the slot number by displaying the controller configuration (see above) |
Status | hpacucli> ctrl slot=0 pd all show status hpacucli> ctrl slot=0 pd 2:3 show status |
Erase | hpacucli> ctrl slot=0 pd 2:3 modify erase |
Blink disk LED | hpacucli> ctrl slot=0 pd 2:3 modify led=on hpacucli> ctrl slot=0 pd 2:3 modify led=off |
Logical Drive Commands
|
|
Display (detailed) | hpacucli> ctrl slot=0 ld all show [detail] hpacucli> ctrl slot=0 ld 4 show [detail] |
Status | hpacucli> ctrl slot=0 ld all show status hpacucli> ctrl slot=0 ld 4 show status |
Blink disk LED | hpacucli> ctrl slot=0 ld 4 modify led=on hpacucli> ctrl slot=0 ld 4 modify led=off |
re-enabling failed drive | hpacucli> ctrl slot=0 ld 4 modify reenable forced |
Create | # logical drive - one disk hpacucli> ctrl slot=0 create type=ld drives=1:12 raid=0 # logical drive - mirrored hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14 size=300 raid=1 # logical drive - raid 5 hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14,1:15,1:16,1:17 raid=5 Note: drives - specific drives, all drives or unassigned drives size - size of the logical drive in MB raid - type of raid 0, 1 , 1+0 and 5 |
Remove | hpacucli> ctrl slot=0 ld 4 delete |
Expanding | hpacucli> ctrl slot=0 ld 4 add drives=2:3 |
Extending | hpacucli> ctrl slot=0 ld 4 modify size=500 forced |
Spare | hpacucli> ctrl slot=0 array all add spares=1:5,1:7 |
No comments: